Abstract AITranslate

Nowadays, flexible triboelectric sensors are the most promising candidates for wearable energy harvesting and medical applications. In the present investigation, the self-powered flexible triboelectric sensors (SF-TESs) were fabricated by using roughness-created Ecoflex cast film and melt-blown nonwoven polyurethane layers. SF-TESs were prepared using sandpaper (60 grit size) as a substrate, showing better triboelectric performance due to high surface roughness and low density compared to others, and it is an optimum condition. The optimized SF-TES can scavenge a maximum open-circuit output voltage (VOC) and power density values for the sensor without and with a spacer were 139 V and 1.6 Wm–2 and 320 V and 6 Wm–2, respectively. The spacer sample showed 2.3 times higher VOC and 3.7 times higher power density values than without a spacer at a constant load of 4.4 N and a frequency of 5 Hz. The SF-TES can directly operate 15 light-emitting diodes (LEDs) and switch on an LCD timer, and it is powered for 5 s when connected through a rectifier and a capacitor. In contrast, the sensor with a spacer can operate more than 100 LEDs directly. Further, the triboelectric output performances VOC and short-circuit current (ISC) gradually increase from 65 to 139 V and 2.3 to 4.6 μA, respectively, when the external load increases from 2.2 to 8.8 N. Based on the above results, we can clearly say that the surface roughness, spacing between the frictional layers, and external load are critical parameters for enhancing the triboelectric performance. The as-prepared SF-TESs have potential medical applications in the intelligent beds for observing the physical activity of coma patients, patients suffering from cardiovascular diseases, and sleep apnea.

KeyWords AITranslate

selfpowered flexible triboelectric sensor (SFTES) opencircuit output voltage (VOC) power density Ecoflex cast film (ECF) surface roughness melt blown nonwoven polyurethane (TPUnw)
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.2c01773

Chinese Library Classification Number:

Citation Information:

Nowadays, flexible triboelectric sensors are the most promising candidates for wearable energy harvesting and medical applications. In the present investigation, the self-powered flexible triboelectric sensors (SF-TESs) were fabricated by using roughness-created Ecoflex cast film and melt-blown nonwoven polyurethane layers. SF-TESs were prepared using sandpaper (60 grit size) as a substrate, showing better triboelectric performance due to high surface roughness and low density compared to others, and it is an optimum condition. The optimized SF-TES can scavenge a maximum open-circuit output voltage (VOC) and power density values for the sensor without and with a spacer were 139 V and 1.6 Wm–2 and 320 V and 6 Wm–2, respectively. The spacer sample showed 2.3 times higher VOC and 3.7 times higher power density values than without a spacer at a constant load of 4.4 N and a frequency of 5 Hz. The SF-TES can directly operate 15 light-emitting diodes (LEDs) and switch on an LCD timer, and it is powered for 5 s when connected through a rectifier and a capacitor. In contrast, the sensor with a spacer can operate more than 100 LEDs directly. Further, the triboelectric output performances VOC and short-circuit current (ISC) gradually increase from 65 to 139 V and 2.3 to 4.6 μA, respectively, when the external load increases from 2.2 to 8.8 N. Based on the above results, we can clearly say that the surface roughness, spacing between the frictional layers, and external load are critical parameters for enhancing the triboelectric performance. The as-prepared SF-TESs have potential medical applications in the intelligent beds for observing the physical activity of coma patients, patients suffering from cardiovascular diseases, and sleep apnea.

quote

GB/T 7714-2015 [1] Prasad Gajula, Fahad Mir Muhammad, Mohammad Shamim Reza, et al. ACS Applied Electronic Materials, 2023(5). DOI:10.1021/acsaelm.2c01773.
MLA [1] Prasad Gajula, et al., ACS Applied Electronic Materials, no. 5, 2023, https://doi.org/10.1021/acsaelm.2c01773.
APA [1] Prasad Gajula, Fahad Mir Muhammad, Mohammad Shamim Reza, Sellamuthu N. Jaisankar, Kap Jin Kim, & Hongdoo Kim. (2023). ACS Applied Electronic Materials(5). https://doi.org/10.1021/acsaelm.2c01773
IEEE [1] Prasad Gajula, Fahad Mir Muhammad, Mohammad Shamim Reza, Sellamuthu N. Jaisankar, Kap Jin Kim, and Hongdoo Kim, ACS Applied Electronic Materials, no. 5, 2023, doi: 10.1021/acsaelm.2c01773. keywords: {selfpowered flexible triboelectric sensor (SFTES) opencircuit output voltage (VOC) power density Ecoflex cast film (ECF) surface roughness melt blown nonwoven polyurethane (TPUnw)}