daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

All-Polymeric Pressure Sensors Based on PEDOT:PSS-Modified Polyurethane Foam AITranslate

Institute of Materials for Electronics and Magnetism (IMEM);Institute of Materials for Electronics and Magnetism (IMEM); University Magna Graecia of Catanzaro; University of Calabria;Institute of Materials for Electronics and Magnetism (IMEM);Institute of Materials for Electronics and Magnetism (IMEM);Institute of Materials for Electronics and Magnetism (IMEM);Institute of Materials for Electronics and Magnetism (IMEM);Institute of Materials for Electronics and Magnetism (IMEM)
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

The ability to produce distributed sensors by tailoring materials readily available on the market is becoming an emerging strategy for Internet of Things applications. Embedding sensors into functional substrates allows one to reduce costs and improve integration and gives unique functionalities inaccessible to silicon or other conventional materials used in microelectronics. In this paper, we demonstrate the functionalization of a commercial polyurethane (PU) foam with the conductive polymer PEDOT:PSS: the resulting material is a modified all-polymeric foam where the internal network of pores is uniformly coated with a continuous layer of PEDOT:PSS acting as a mechanical transducer. When an external force causes a modification of the foam microstructure, the conductivity of the device varies accordingly, enabling the conversion of a mechanical pressure into an electric signal. The sensor provides a nearly linear response when stimulated by an external pressure in the range between 0.1 and 20 kPa. Frequency-dependent measurements show a useful frequency range up to 20 Hz. A simple micromechanical model has been proposed to predict the device performance based on the characteristics of the system, including geometrical constrains, the microstructure of the polymeric foam, and its elastic modulus. By taking advantage of the simulation output, a flexible shoe in sole prototype has been developed by embedding eight pressure sensors into a commercial PU foam. The proposed device may provide critical information to medical teams, such as the real-time bodyweight distribution and a detailed representation of the walking dynamic.

KeyWords AITranslate

polymeric pressure sensor active orthopedic insole PEDOT:PSS conductive sponge postural monitoring
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.0c01389

Chinese Library Classification Number:

Citation Information:

The ability to produce distributed sensors by tailoring materials readily available on the market is becoming an emerging strategy for Internet of Things applications. Embedding sensors into functional substrates allows one to reduce costs and improve integration and gives unique functionalities inaccessible to silicon or other conventional materials used in microelectronics. In this paper, we demonstrate the functionalization of a commercial polyurethane (PU) foam with the conductive polymer PEDOT:PSS: the resulting material is a modified all-polymeric foam where the internal network of pores is uniformly coated with a continuous layer of PEDOT:PSS acting as a mechanical transducer. When an external force causes a modification of the foam microstructure, the conductivity of the device varies accordingly, enabling the conversion of a mechanical pressure into an electric signal. The sensor provides a nearly linear response when stimulated by an external pressure in the range between 0.1 and 20 kPa. Frequency-dependent measurements show a useful frequency range up to 20 Hz. A simple micromechanical model has been proposed to predict the device performance based on the characteristics of the system, including geometrical constrains, the microstructure of the polymeric foam, and its elastic modulus. By taking advantage of the simulation output, a flexible shoe in sole prototype has been developed by embedding eight pressure sensors into a commercial PU foam. The proposed device may provide critical information to medical teams, such as the real-time bodyweight distribution and a detailed representation of the walking dynamic.

quote

GB/T 7714-2015 [1] Matteo Beccatelli, Marco Villani, Francesco Gentile, et al. ACS Applied Polymer Materials, 2021(3). DOI:10.1021/acsapm.0c01389.
MLA [1] Matteo Beccatelli, et al., ACS Applied Polymer Materials, no. 3, 2021, https://doi.org/10.1021/acsapm.0c01389.
APA [1] Matteo Beccatelli, Marco Villani, Francesco Gentile, Luigi Bruno, Davide Seletti, Domna Maria Nikolaidou, Maurizio Culiolo, Andrea Zappettini, & Nicola Coppedè. (2021). ACS Applied Polymer Materials(3). https://doi.org/10.1021/acsapm.0c01389
IEEE [1] Matteo Beccatelli, Marco Villani, Francesco Gentile, Luigi Bruno, Davide Seletti, Domna Maria Nikolaidou, Maurizio Culiolo, Andrea Zappettini, and Nicola Coppedè, ACS Applied Polymer Materials, no. 3, 2021, doi: 10.1021/acsapm.0c01389. keywords: {polymeric pressure sensor;active orthopedic insole;PEDOT:PSS;conductive sponge;postural monitoring}