Ultralow-Power and Miniaturized X-ray Sensor Using the Single-Walled Carbon Nanotube Micro Network-Based Geiger Counter Design AITranslate
Abstract AITranslate
We present an ultralow-power, highly sensitive, and miniaturized X-ray sensor with micropatterned single-walled carbon nanotube (SWCNT) interdigitated networks inspired by the Geiger-Mueller counter design. Due to the unique nanostructured surface and superb electronic transport nature of assembled SWCNTs, a strong electric field is formed between and within highly organized SWCNT interdigitated electrodes, which effectively separates electrons and ionized ions created by incident X-rays into electrodes, facilitating electron detection. As a result, the device can detect a low X-ray dose rate (9.97 μGy·s–1) with an extremely low power consumption of 80–90 fW, demonstrating a sensitivity of up to 203.96 μC·Gy–1·cm–2. Furthermore, the interdigitated SWCNT electrode design produces a low noise level in the picoampere range, permitting exceptional real-time signal detection during X-ray exposure. These unique features of our SWCNT X-ray sensing device enable various low SWaP (size, weight, and power) radiation detectors in the fields of medicine, homeland security, and defense.
KeyWords AITranslate
Basic Information:
DOI:https://doi.org/10.1021/acsaelm.2c00600
Chinese Library Classification Number:
Citation Information:
We present an ultralow-power, highly sensitive, and miniaturized X-ray sensor with micropatterned single-walled carbon nanotube (SWCNT) interdigitated networks inspired by the Geiger-Mueller counter design. Due to the unique nanostructured surface and superb electronic transport nature of assembled SWCNTs, a strong electric field is formed between and within highly organized SWCNT interdigitated electrodes, which effectively separates electrons and ionized ions created by incident X-rays into electrodes, facilitating electron detection. As a result, the device can detect a low X-ray dose rate (9.97 μGy·s–1) with an extremely low power consumption of 80–90 fW, demonstrating a sensitivity of up to 203.96 μC·Gy–1·cm–2. Furthermore, the interdigitated SWCNT electrode design produces a low noise level in the picoampere range, permitting exceptional real-time signal detection during X-ray exposure. These unique features of our SWCNT X-ray sensing device enable various low SWaP (size, weight, and power) radiation detectors in the fields of medicine, homeland security, and defense.
quote
| GB/T 7714-2015 | [1] Hyehee Kim, Jianlin Li, Anthony Childress, et al. ACS Applied Electronic Materials, 2022(4). DOI:10.1021/acsaelm.2c00600. |
| MLA | [1] Hyehee Kim, et al., ACS Applied Electronic Materials, no. 4, 2022, https://doi.org/10.1021/acsaelm.2c00600. |
| APA | [1] Hyehee Kim, Jianlin Li, Anthony Childress, Juyeon Seo, Poornaprakash Bathalavaram, Ahmed Busnaina, SungHyun Moon, Jihwan Boo, Hak Soo Choi, Geehyun Kim, Young Lae Kim, & Yung Joon Jung. (2022). ACS Applied Electronic Materials(4). https://doi.org/10.1021/acsaelm.2c00600 |
| IEEE | [1] Hyehee Kim, Jianlin Li, Anthony Childress, Juyeon Seo, Poornaprakash Bathalavaram, Ahmed Busnaina, SungHyun Moon, Jihwan Boo, Hak Soo Choi, Geehyun Kim, Young Lae Kim, and Yung Joon Jung, ACS Applied Electronic Materials, no. 4, 2022, doi: 10.1021/acsaelm.2c00600. keywords: {realtime Xray detector ultralowpower consumption Xray profiling instant recovery time SWCNT micro Geiger counter} |