daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Rapid Detection of Inflammation-Related Biomarkers Using an Electrochemical Sensor Modified with a PBNC-AuNS-GO-Based Nanocomposite AITranslate

Sungkyunkwan University; Sungkyunkwan University; Sungkyunkwan University; Sungkyunkwan University
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Inflammation is the immune system response when the healthy tissues of the body are damaged by different factors, such as bacteria, viruses, and toxins. Also, when widespread inflammation happens in the body, it can lead to specific conditions that are a significant cause of hospital morbidity and mortality worldwide, e.g., sepsis. Though many inflammation-related biomarkers can be used for the diagnosis of the clinical syndrome, most of the standard tests have a long turnaround time, high cost, and the need for medically trained personnel. Considering the urgency to develop a faster and multitarget method to prevent the aggravation of inflammatory responses using a small volume of human blood samples, herein is the first part of a study focusing on the design and fabrication of a flexible polymer-based device, with a metal-based nanocomposite, to detect three inflammation-related biomarkers (lactate, C-reactive protein, and interleukin-6) that are also detected in high levels during the different stages of inflammation. The working electrode surface was modified with Prussian blue nanocubes, gold nanostars, and graphene oxide to improve the sensitivity and selectivity, enhancing the surface area, electrical conductivity, and electroactivity. Differential pulse voltammetry measurements were recorded while the serum sample was injected with different target concentrations in the channel. The bioreceptors recognize and bind the targets changing the peak currents based on the concentration in the buffer solution. The results show a linear behavior, with high values (>0.99) for the correlation coefficients, supporting the relationship between the concentration of inflammation-related markers and the electrical current. With the improvement in the device structure to be adapted as a portable reader connected to a smartphone, the proposed method is validated to provide a point-of-care diagnosis of septic shock in the emergency department of hospitals using a small volume of samples.

KeyWords AITranslate

nanocomposite layer electrochemical sensor multiple detections inflammationrelated biomarkers metal nanostructures
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.2c00701

Chinese Library Classification Number:

Citation Information:

Inflammation is the immune system response when the healthy tissues of the body are damaged by different factors, such as bacteria, viruses, and toxins. Also, when widespread inflammation happens in the body, it can lead to specific conditions that are a significant cause of hospital morbidity and mortality worldwide, e.g., sepsis. Though many inflammation-related biomarkers can be used for the diagnosis of the clinical syndrome, most of the standard tests have a long turnaround time, high cost, and the need for medically trained personnel. Considering the urgency to develop a faster and multitarget method to prevent the aggravation of inflammatory responses using a small volume of human blood samples, herein is the first part of a study focusing on the design and fabrication of a flexible polymer-based device, with a metal-based nanocomposite, to detect three inflammation-related biomarkers (lactate, C-reactive protein, and interleukin-6) that are also detected in high levels during the different stages of inflammation. The working electrode surface was modified with Prussian blue nanocubes, gold nanostars, and graphene oxide to improve the sensitivity and selectivity, enhancing the surface area, electrical conductivity, and electroactivity. Differential pulse voltammetry measurements were recorded while the serum sample was injected with different target concentrations in the channel. The bioreceptors recognize and bind the targets changing the peak currents based on the concentration in the buffer solution. The results show a linear behavior, with high values (>0.99) for the correlation coefficients, supporting the relationship between the concentration of inflammation-related markers and the electrical current. With the improvement in the device structure to be adapted as a portable reader connected to a smartphone, the proposed method is validated to provide a point-of-care diagnosis of septic shock in the emergency department of hospitals using a small volume of samples.

quote

GB/T 7714-2015 [1] Ariadna Schuck, Hyo Eun Kim, Minhee Kang, et al. ACS Applied Electronic Materials, 2022(4). DOI:10.1021/acsaelm.2c00701.
MLA [1] Ariadna Schuck, et al., ACS Applied Electronic Materials, no. 4, 2022, https://doi.org/10.1021/acsaelm.2c00701.
APA [1] Ariadna Schuck, Hyo Eun Kim, Minhee Kang, & YongSang Kim. (2022). ACS Applied Electronic Materials(4). https://doi.org/10.1021/acsaelm.2c00701
IEEE [1] Ariadna Schuck, Hyo Eun Kim, Minhee Kang, and YongSang Kim, ACS Applied Electronic Materials, no. 4, 2022, doi: 10.1021/acsaelm.2c00701. keywords: {nanocomposite layer electrochemical sensor multiple detections inflammationrelated biomarkers metal nanostructures}