daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Molecular Weight Characterization of Conjugated Polymers Through Gel Permeation Chromatography and Static Light Scattering AITranslate

University Park; University Park; New Mexico Institute of Mining and Technology; University Park; University Park
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Molecular weight is a key parameter of any polymer. Characterizing the molecular weight of conjugated polymers is often nontrivial due to their semiflexible backbones and poor solubilities. Perhaps the most used technique for measuring the molecular weight is gel permeation chromatography (GPC), and results are often calibrated relative to flexible polymer standards. This mismatch between chain flexibilities of samples and standards, combined with poor sample solubility in the mobile phase, leads to inaccuracies in many GPC measurements of conjugated polymers. In this work, we use a universal calibration combined with in-line concentration measurements to yield reliably accurate results for polymers of various stiffnesses. Accuracy of results is verified with absolute molecular weights obtained from static light scattering. We show that measuring the refractive index increment is key to confirm full recovery of the polymer and ensure accurate values of the absolute molecular weight from GPC.

KeyWords AITranslate

size exclusion chromatography intrinsic viscosity static light scattering radius of gyration refractive index increment
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.1c00647

Chinese Library Classification Number:

Citation Information:

Molecular weight is a key parameter of any polymer. Characterizing the molecular weight of conjugated polymers is often nontrivial due to their semiflexible backbones and poor solubilities. Perhaps the most used technique for measuring the molecular weight is gel permeation chromatography (GPC), and results are often calibrated relative to flexible polymer standards. This mismatch between chain flexibilities of samples and standards, combined with poor sample solubility in the mobile phase, leads to inaccuracies in many GPC measurements of conjugated polymers. In this work, we use a universal calibration combined with in-line concentration measurements to yield reliably accurate results for polymers of various stiffnesses. Accuracy of results is verified with absolute molecular weights obtained from static light scattering. We show that measuring the refractive index increment is key to confirm full recovery of the polymer and ensure accurate values of the absolute molecular weight from GPC.

quote

GB/T 7714-2015 [1] Ryan A. Fair, Renxuan Xie, Youngmin Lee, et al. ACS Applied Polymer Materials, 2021(3). DOI:10.1021/acsapm.1c00647.
MLA [1] Ryan A. Fair, et al., ACS Applied Polymer Materials, no. 3, 2021, https://doi.org/10.1021/acsapm.1c00647.
APA [1] Ryan A. Fair, Renxuan Xie, Youngmin Lee, Ralph H. Colby, & Enrique D. Gomez. (2021). ACS Applied Polymer Materials(3). https://doi.org/10.1021/acsapm.1c00647
IEEE [1] Ryan A. Fair, Renxuan Xie, Youngmin Lee, Ralph H. Colby, and Enrique D. Gomez, ACS Applied Polymer Materials, no. 3, 2021, doi: 10.1021/acsapm.1c00647. keywords: {size exclusion chromatography;intrinsic viscosity;static light scattering;radius of gyration;refractive index increment}