Silicon Doping by Polymer Grafting: Size Distribution Matters AITranslate

IMM-CNR Agrate Unit, Via C. Olivetti 2;IMM-CNR Agrate Unit, Via C. Olivetti 2;IMM-CNR Agrate Unit, Via C. Olivetti 2;IMM-CNR Agrate Unit, Via C. Olivetti 2;Università del Piemonte Orientale “A. Avogadro”, Viale T. Michel 11;Università del Piemonte Orientale “A. Avogadro”, Viale T. Michel 11;Università del Piemonte Orientale “A. Avogadro”, Viale T. Michel 11;Università del Piemonte Orientale “A. Avogadro”, Viale T. Michel 11
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Phosphorus δ-layers in SiO2 have been prepared by means of poly(methyl methacrylate) (PMMA), terminated with a phosphorus-containing moiety acting as an anchoring group. In particular, grafting of two P-terminated PMMA samples with Mn = 7.5 kg/mol (D̵ = 1.14) and Mn = 17.8 kg/mol (D̵ = 1.23) onto 10 nm thick SiO2 films deposited on Si substrates has been investigated, focusing on the thickness evolution of the brush layer as a function of the processing parameters, that is, annealing temperature and time. Upon removal of the polymer chains and subsequent encapsulation into a SiO2 matrix, the concentration of phosphorus atoms into the P δ-layers has been monitored by time-of-flight secondary ion mass spectrometry. The effective P dose in the P δ-layer is mainly dictated by the molecular weight of the P-terminated PMMA, and the doping process results are highly reproducible, provided that tight control over the experimental protocol is granted. However, although the grafting density is expected to progressively increase as a function of annealing time with a linear correlation between grafting density and thickness, the measured P dose in the δ-layers is observed to follow the opposite trend. This effect has been accounted for by considering a distortion of the molecular weight distribution of the grafted species with respect to the initial molecular weight distribution of the polymer. The overall picture reveals important information about the mechanism and dynamics governing the “grafting to” process of P-terminated PMMA polymers onto nondeglazed Si substrates.

KeyWords AITranslate

doping silicon polymers phosphorus activation selfassembled monolayers
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.1c01157

Chinese Library Classification Number:

Citation Information:

Phosphorus δ-layers in SiO2 have been prepared by means of poly(methyl methacrylate) (PMMA), terminated with a phosphorus-containing moiety acting as an anchoring group. In particular, grafting of two P-terminated PMMA samples with Mn = 7.5 kg/mol (D̵ = 1.14) and Mn = 17.8 kg/mol (D̵ = 1.23) onto 10 nm thick SiO2 films deposited on Si substrates has been investigated, focusing on the thickness evolution of the brush layer as a function of the processing parameters, that is, annealing temperature and time. Upon removal of the polymer chains and subsequent encapsulation into a SiO2 matrix, the concentration of phosphorus atoms into the P δ-layers has been monitored by time-of-flight secondary ion mass spectrometry. The effective P dose in the P δ-layer is mainly dictated by the molecular weight of the P-terminated PMMA, and the doping process results are highly reproducible, provided that tight control over the experimental protocol is granted. However, although the grafting density is expected to progressively increase as a function of annealing time with a linear correlation between grafting density and thickness, the measured P dose in the δ-layers is observed to follow the opposite trend. This effect has been accounted for by considering a distortion of the molecular weight distribution of the grafted species with respect to the initial molecular weight distribution of the polymer. The overall picture reveals important information about the mechanism and dynamics governing the “grafting to” process of P-terminated PMMA polymers onto nondeglazed Si substrates.

quote

GB/T 7714-2015 [1] Michele Perego, Stefano Kuschlan, Gabriele Seguini, et al. ACS Applied Polymer Materials, 2021(3). DOI:10.1021/acsapm.1c01157.
MLA [1] Michele Perego, et al., ACS Applied Polymer Materials, no. 3, 2021, https://doi.org/10.1021/acsapm.1c01157.
APA [1] Michele Perego, Stefano Kuschlan, Gabriele Seguini, Riccardo Chiarcos, Valentina Gianotti, Diego Antonioli, Katia Sparnacci, & Michele Laus. (2021). ACS Applied Polymer Materials(3). https://doi.org/10.1021/acsapm.1c01157
IEEE [1] Michele Perego, Stefano Kuschlan, Gabriele Seguini, Riccardo Chiarcos, Valentina Gianotti, Diego Antonioli, Katia Sparnacci, and Michele Laus, ACS Applied Polymer Materials, no. 3, 2021, doi: 10.1021/acsapm.1c01157. keywords: {doping;silicon;polymers;phosphorus;activation;selfassembled monolayers}