Enhancing NIR-II Phosphorescence through Phosphorescence Resonance Energy Transfer for Tumor-Hypoxia Imaging AITranslate
Abstract AITranslate
Phosphorescence probes have emerged as a promising hypoxia detector for their excellent characters of long luminescence lifetime, large Stokes shift, and oxygen sensitivity. However, the low quantum yields of organic phosphorescence probes in the second near-infrared wavelength window (NIR-II, 1000–1700 nm) hinder their further development of NIR-II hypoxia imaging. Herein, this study reports a new NIR-II phosphorescence probe (PRET NPs) containing a phosphorescent long-lived triplet energy donor (PD) and a NIR-II fluorescent energy acceptor (FA) by using phosphorescence resonance energy transfer (PRET) strategy. Because of the suitable spectral overlap of PD and FA, PRET NPs exhibit high NIR-II quantum yield in both normoxic and oxygen-free atmospheres. Based on that, in the in vivo tumor hypoxia imaging experiments, PRET NPs also exhibit high brightness and signal-to-background ratio (SBR) of NIR-II tumor-hypoxia imaging. Therefore, this study illustrates a general approach based on “PRET” strategy to develop bright NIR-II phosphorescent probes.
KeyWords AITranslate
Basic Information:
DOI:https://doi.org/10.1021/acsmaterialslett.2c01033
Chinese Library Classification Number:
Citation Information:
Phosphorescence probes have emerged as a promising hypoxia detector for their excellent characters of long luminescence lifetime, large Stokes shift, and oxygen sensitivity. However, the low quantum yields of organic phosphorescence probes in the second near-infrared wavelength window (NIR-II, 1000–1700 nm) hinder their further development of NIR-II hypoxia imaging. Herein, this study reports a new NIR-II phosphorescence probe (PRET NPs) containing a phosphorescent long-lived triplet energy donor (PD) and a NIR-II fluorescent energy acceptor (FA) by using phosphorescence resonance energy transfer (PRET) strategy. Because of the suitable spectral overlap of PD and FA, PRET NPs exhibit high NIR-II quantum yield in both normoxic and oxygen-free atmospheres. Based on that, in the in vivo tumor hypoxia imaging experiments, PRET NPs also exhibit high brightness and signal-to-background ratio (SBR) of NIR-II tumor-hypoxia imaging. Therefore, this study illustrates a general approach based on “PRET” strategy to develop bright NIR-II phosphorescent probes.
quote
| GB/T 7714-2015 | [1] Wansu Zhang, Shangyu Chen, Shuai Ye, et al. ACS Materials Letters, 2023(5). DOI:10.1021/acsmaterialslett.2c01033. |
| MLA | [1] Wansu Zhang, et al., ACS Materials Letters, no. 5, 2023, https://doi.org/10.1021/acsmaterialslett.2c01033. |
| APA | [1] Wansu Zhang, Shangyu Chen, Shuai Ye, Pengfei Sun, Quli Fan, Jun Song, Pengju Zeng, JunLe Qu, & WaiYeung Wong. (2023). ACS Materials Letters(5). https://doi.org/10.1021/acsmaterialslett.2c01033 |
| IEEE | [1] Wansu Zhang, Shangyu Chen, Shuai Ye, Pengfei Sun, Quli Fan, Jun Song, Pengju Zeng, JunLe Qu, and WaiYeung Wong, ACS Materials Letters, no. 5, 2023, doi: 10.1021/acsmaterialslett.2c01033. |
