VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;Graphenea Semiconductor SLU, Paseo Mikeletegi 83;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;Graphenea Semiconductor SLU, Paseo Mikeletegi 83;Graphenea Semiconductor SLU, Paseo Mikeletegi 83;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;Graphenea Semiconductor SLU, Paseo Mikeletegi 83;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000;VTT Technical Research Centre of Finland Ltd, P.O. Box 1000
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

The reliability of analysis is becoming increasingly important as point-of-care diagnostics are transitioning from single-analyte detection toward multiplexed multianalyte detection. Multianalyte detection benefits greatly from complementary metal-oxide semiconductor (CMOS) integrated sensing solutions, offering miniaturized multiplexed sensing arrays with integrated readout electronics and extremely large sensor counts. The development of CMOS back end of line integration compatible graphene field-effect transistor (GFET)-based biosensing has been rapid during the past few years, in terms of both the fabrication scale-up and functionalization toward biorecognition from real sample matrices. The next steps in industrialization relate to improving reliability and require increased statistics. Regarding functionalization toward truly quantitative sensors, on-chip bioassays with improved statistics require sensor arrays with reduced variability in functionalization. Such multiplexed bioassays, whether based on graphene or on other sensitive nanomaterials, are among the most promising technologies for label-free electrical biosensing. As an important step toward that, we report wafer-scale fabrication of CMOS-integrated GFET arrays with high yield and uniformity, designed especially for biosensing applications. We demonstrate the operation of the sensing platform array with 512 GFETs in simultaneous detection for the sodium chloride concentration series. This platform offers a truly statistical approach on GFET-based biosensing and further to quantitative and multianalyte sensing. The reported techniques can also be applied to other fields relying on functionalized GFETs, such as gas or chemical sensing or infrared imaging.

KeyWords AITranslate

graphene CMOS monolithic integration waferscale fieldeffect transistor biosensor statistics
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.3c00706

Chinese Library Classification Number:

Citation Information:

The reliability of analysis is becoming increasingly important as point-of-care diagnostics are transitioning from single-analyte detection toward multiplexed multianalyte detection. Multianalyte detection benefits greatly from complementary metal-oxide semiconductor (CMOS) integrated sensing solutions, offering miniaturized multiplexed sensing arrays with integrated readout electronics and extremely large sensor counts. The development of CMOS back end of line integration compatible graphene field-effect transistor (GFET)-based biosensing has been rapid during the past few years, in terms of both the fabrication scale-up and functionalization toward biorecognition from real sample matrices. The next steps in industrialization relate to improving reliability and require increased statistics. Regarding functionalization toward truly quantitative sensors, on-chip bioassays with improved statistics require sensor arrays with reduced variability in functionalization. Such multiplexed bioassays, whether based on graphene or on other sensitive nanomaterials, are among the most promising technologies for label-free electrical biosensing. As an important step toward that, we report wafer-scale fabrication of CMOS-integrated GFET arrays with high yield and uniformity, designed especially for biosensing applications. We demonstrate the operation of the sensing platform array with 512 GFETs in simultaneous detection for the sodium chloride concentration series. This platform offers a truly statistical approach on GFET-based biosensing and further to quantitative and multianalyte sensing. The reported techniques can also be applied to other fields relying on functionalized GFETs, such as gas or chemical sensing or infrared imaging.

quote

GB/T 7714-2015 [1] Miika Soikkeli, Anton Murros, Arto Rantala, et al. ACS Applied Electronic Materials, 2023(5). DOI:10.1021/acsaelm.3c00706.
MLA [1] Miika Soikkeli, et al., ACS Applied Electronic Materials, no. 5, 2023, https://doi.org/10.1021/acsaelm.3c00706.
APA [1] Miika Soikkeli, Anton Murros, Arto Rantala, Oihana Txoperena, OlliPekka Kilpi, Markku Kainlauri, Kuura Sovanto, Arantxa Maestre, Alba Centeno, Kari Tukkiniemi, David Gomes Martins, Amaia Zurutuza, Sanna Arpiainen, & Mika Prunnila. (2023). ACS Applied Electronic Materials(5). https://doi.org/10.1021/acsaelm.3c00706
IEEE [1] Miika Soikkeli, Anton Murros, Arto Rantala, Oihana Txoperena, OlliPekka Kilpi, Markku Kainlauri, Kuura Sovanto, Arantxa Maestre, Alba Centeno, Kari Tukkiniemi, David Gomes Martins, Amaia Zurutuza, Sanna Arpiainen, and Mika Prunnila, ACS Applied Electronic Materials, no. 5, 2023, doi: 10.1021/acsaelm.3c00706. keywords: {graphene CMOS monolithic integration waferscale fieldeffect transistor biosensor statistics}