Beijing University of Civil Engineering and Architecture; Beijing University of Civil Engineering and Architecture; Beijing University of Civil Engineering and Architecture; Beijing University of Civil Engineering and Architecture;Beijing Institute of Architectural Design;Beijing Institute of Architectural Design;Beijing Institute of Architectural Design
AITranslate
Publisher: Elsevier
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Connection performance of grouted sleeves in precast concrete (PC) structures is a critical issue. This research addressed the widely observed insufficient grouting problem of grouted sleeve connections (GSCs). A defect-detectable and repairable half-grouted sleeve (DDRHGS) was developed, and a quantitative detection and repair method, as well as associated endoscopic equipment, was recommended. The detectability and repairability of the DDRHGS were then validated through laboratory tests and field work in real engineering practice. Subsequently, to further investigate the effect of grouting defect ratios on the tensile performance of the DDRHGS and verify the connection performance after repair, uniaxial tensile tests were conducted on 26 groups with 78 GSCs, which included GSCs with and without defects, as well as repaired GSCs. The influences of the rebar diameter, defect ratio, and repair material on the failure mode and mechanical characteristics of the GSCs were investigated. The test results indicated that the defect ratio significantly affected the connection performance of GSCs. A high defect ratio led to bar slip instead of the expected bar fracture observed for the specimens without defects, and the strength and deformation capacities of such specimens could not meet the requirements of the codes. Approximately identical failure modes and mechanical characteristics were observed between the 48 repaired specimens and specimens without defects, thus conclusively verifying the feasibility, necessity, and reliability of the defect detection and repair method for GSCs.

KeyWords AITranslate

Grouted sleeve connection Insufficient grouting Defect detection and repair Defect ratio Tensile performance
No data

Basic Information:

DOI:https://doi.org/10.1016/j.cscm.2022.e01205

Chinese Library Classification Number:

Citation Information:

Connection performance of grouted sleeves in precast concrete (PC) structures is a critical issue. This research addressed the widely observed insufficient grouting problem of grouted sleeve connections (GSCs). A defect-detectable and repairable half-grouted sleeve (DDRHGS) was developed, and a quantitative detection and repair method, as well as associated endoscopic equipment, was recommended. The detectability and repairability of the DDRHGS were then validated through laboratory tests and field work in real engineering practice. Subsequently, to further investigate the effect of grouting defect ratios on the tensile performance of the DDRHGS and verify the connection performance after repair, uniaxial tensile tests were conducted on 26 groups with 78 GSCs, which included GSCs with and without defects, as well as repaired GSCs. The influences of the rebar diameter, defect ratio, and repair material on the failure mode and mechanical characteristics of the GSCs were investigated. The test results indicated that the defect ratio significantly affected the connection performance of GSCs. A high defect ratio led to bar slip instead of the expected bar fracture observed for the specimens without defects, and the strength and deformation capacities of such specimens could not meet the requirements of the codes. Approximately identical failure modes and mechanical characteristics were observed between the 48 repaired specimens and specimens without defects, thus conclusively verifying the feasibility, necessity, and reliability of the defect detection and repair method for GSCs.

quote

GB/T 7714-2015 [1] Linlin Xie, Xinyu Wang, Cantian Yang, et al. Case Studies in Construction Materials, 2022(17). DOI:10.1016/j.cscm.2022.e01205.
MLA [1] Linlin Xie, et al., Case Studies in Construction Materials, no. 17, 2022, https://doi.org/10.1016/j.cscm.2022.e01205.
APA [1] Linlin Xie, Xinyu Wang, Cantian Yang, Yonghui Jiang, Qianmin Liu, Qisong Miao, & Xi Chen. (2022). Case Studies in Construction Materials(17). https://doi.org/10.1016/j.cscm.2022.e01205
IEEE [1] Linlin Xie, Xinyu Wang, Cantian Yang, Yonghui Jiang, Qianmin Liu, Qisong Miao, and Xi Chen, Case Studies in Construction Materials, no. 17, 2022, doi: 10.1016/j.cscm.2022.e01205. keywords: {Grouted sleeve connection;Insufficient grouting;Defect detection and repair;Defect ratio;Tensile performance}