We have investigated the electromagnetic interference (EMI) shielding effect of copper conducting films prepared by electroless plating. The various EMI shielding films were made at different plating times (10, 20, 30, and 40 min). The influences of pretreatment and plating time on microstructure, thickness, adhesion (e.g., cross-cutting and pencil hardness), and electromagnetic shielding effectiveness were evaluated. The morphological features and thickness of EMI shielding films were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD) methods. The experimental results show that the best outcome of adhesion and electromagnetic shielding effectiveness was obtained at the pretreated film with 30 min of plating time. The pretreated film showed a cross-cutting 5B grade, 4H pencil hardness, and 75 dB shielding effectiveness. The results of electromagnetic shielding effectiveness of films indicate that a longer plating time (10–30 min) results in better electromagnetic shielding effectiveness. However, the adhesive strength becomes worse if the plating time is longer than 40 min.

KeyWords AITranslate

electromagnetic interference electroless plating shielding effectiveness crosscutting pencil hardness
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.1c01195

Chinese Library Classification Number:

Citation Information:

We have investigated the electromagnetic interference (EMI) shielding effect of copper conducting films prepared by electroless plating. The various EMI shielding films were made at different plating times (10, 20, 30, and 40 min). The influences of pretreatment and plating time on microstructure, thickness, adhesion (e.g., cross-cutting and pencil hardness), and electromagnetic shielding effectiveness were evaluated. The morphological features and thickness of EMI shielding films were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD) methods. The experimental results show that the best outcome of adhesion and electromagnetic shielding effectiveness was obtained at the pretreated film with 30 min of plating time. The pretreated film showed a cross-cutting 5B grade, 4H pencil hardness, and 75 dB shielding effectiveness. The results of electromagnetic shielding effectiveness of films indicate that a longer plating time (10–30 min) results in better electromagnetic shielding effectiveness. However, the adhesive strength becomes worse if the plating time is longer than 40 min.

quote

GB/T 7714-2015 [1] Jae Pil Jung, JungHyun Lee, Ashutosh Sharma. ACS Applied Electronic Materials, 2022(4). DOI:10.1021/acsaelm.1c01195.
MLA [1] Jae Pil Jung, et al., ACS Applied Electronic Materials, no. 4, 2022, https://doi.org/10.1021/acsaelm.1c01195.
APA [1] Jae Pil Jung, JungHyun Lee, & Ashutosh Sharma. (2022). ACS Applied Electronic Materials(4). https://doi.org/10.1021/acsaelm.1c01195
IEEE [1] Jae Pil Jung, JungHyun Lee, and Ashutosh Sharma, ACS Applied Electronic Materials, no. 4, 2022, doi: 10.1021/acsaelm.1c01195. keywords: {electromagnetic interference electroless plating shielding effectiveness crosscutting pencil hardness}