daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Localized Surface Plasmon Resonance-Modulated Graphene-Based Optical Sensor for Ultrasensitive Immunoassays AITranslate

Nankai University; Taiyuan University of Technology; Taiyuan University of Technology; Taiyuan University of Technology; Taiyuan University of Technology; Nankai University
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Quantitative detection of disease markers at ultralow concentrations has rigorous requirements on the performance of graphene-based optical sensors (GOSs). In this work, a localized surface plasmon resonance-modulated GOS was developed by uniformly dispersing gold nanorods (AuNRs) on the graphene surface. As an optical sensor based on refractive index sensing, the refractive index resolution and sensitivity of the optical sensor reached 2.34 × 10–9 and 2.14 × 107 mV/RIU, respectively. The sensitivity of the optical sensor toward IgG immunoassay reached 6.5 mV (μg mL–1)−1, a value 7-fold that without the AuNRs. A limit of detection of 1.22 ng/mL toward IgG immunoassay was obtained, a value one-tenth that without the AuNRs. Most critically, it has been demonstrated that the improved performance of the optical sensor was attributed to the enhanced evanescent field on graphene caused by the coupling of the evanescent field and LSRR of AuNRs. The proposed optical sensor in this study has the characteristics of high sensitivity, being label-free, and a simple preparation process. The successful application of the proposed sensor will also greatly promote the development of quantitative detection of disease markers at ultralow concentrations.

KeyWords AITranslate

graphene gold nanorods refractive index sensing sensitivity enhancement ultrasensitive immunoassay
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.2c01616

Chinese Library Classification Number:

Citation Information:

Quantitative detection of disease markers at ultralow concentrations has rigorous requirements on the performance of graphene-based optical sensors (GOSs). In this work, a localized surface plasmon resonance-modulated GOS was developed by uniformly dispersing gold nanorods (AuNRs) on the graphene surface. As an optical sensor based on refractive index sensing, the refractive index resolution and sensitivity of the optical sensor reached 2.34 × 10–9 and 2.14 × 107 mV/RIU, respectively. The sensitivity of the optical sensor toward IgG immunoassay reached 6.5 mV (μg mL–1)−1, a value 7-fold that without the AuNRs. A limit of detection of 1.22 ng/mL toward IgG immunoassay was obtained, a value one-tenth that without the AuNRs. Most critically, it has been demonstrated that the improved performance of the optical sensor was attributed to the enhanced evanescent field on graphene caused by the coupling of the evanescent field and LSRR of AuNRs. The proposed optical sensor in this study has the characteristics of high sensitivity, being label-free, and a simple preparation process. The successful application of the proposed sensor will also greatly promote the development of quantitative detection of disease markers at ultralow concentrations.

quote

GB/T 7714-2015 [1] Xiaoguang Gao, Lingyu Li, Rong Deng, et al. ACS Applied Electronic Materials, 2023(5). DOI:10.1021/acsaelm.2c01616.
MLA [1] Xiaoguang Gao, et al., ACS Applied Electronic Materials, no. 5, 2023, https://doi.org/10.1021/acsaelm.2c01616.
APA [1] Xiaoguang Gao, Lingyu Li, Rong Deng, Wenjuan Zhao, Xiaoliang Zhang, & Zhibo Liu. (2023). ACS Applied Electronic Materials(5). https://doi.org/10.1021/acsaelm.2c01616
IEEE [1] Xiaoguang Gao, Lingyu Li, Rong Deng, Wenjuan Zhao, Xiaoliang Zhang, and Zhibo Liu, ACS Applied Electronic Materials, no. 5, 2023, doi: 10.1021/acsaelm.2c01616. keywords: {graphene gold nanorods refractive index sensing sensitivity enhancement ultrasensitive immunoassay}