daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Construction of Collagen Methacrylamide Microspheres to Modify Nonwoven Polyamide Fibers Based on Click Chemistry AITranslate

Shaanxi University of Science and Technology; Shaanxi University of Science and Technology; Shaanxi University of Science and Technology
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Using waste leather collagen, collagen microspheres with “–CH═CH2” (CMAs) were prepared using the emulsification cross-linking method and then incorporated into a nonwoven polyamide fiber material with the “thiol–ene” click chemistry method to obtain modified nonwoven polyamide fibers (PA-CMAs). Experiments showed that for a CMA concentration of 6 wt %, initiator concentration of 0.008 wt %, and irradiation time of 5 h, the grafting rate can reach 25.83%. Scanning electron microscope (SEM) and X-ray photoelectron spectrometer (XPS) are used to confirm the successful grafting of CMAs onto nonwoven PA materials. The stability and fastness test was used to show that PA-CMAs have good stability with acid, alkali, organic solvent resistance, and rubbing resistance. The contrast test indicated that the moisture absorption and permeability of PA-CMAs were better than those of nonwoven polyamide/polyurethane (PA/PU), which is a synthetic leather-based material considered as one of the mainstream products. In addition, PA-CMAs maintained the original softness and elastoplasticity of PA.

KeyWords AITranslate

waste leather collagen collagen microspheres nonwoven polyamide fibers moisture absorption and permeability Show More
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.1c01343

Chinese Library Classification Number:

Citation Information:

Using waste leather collagen, collagen microspheres with “–CH═CH2” (CMAs) were prepared using the emulsification cross-linking method and then incorporated into a nonwoven polyamide fiber material with the “thiol–ene” click chemistry method to obtain modified nonwoven polyamide fibers (PA-CMAs). Experiments showed that for a CMA concentration of 6 wt %, initiator concentration of 0.008 wt %, and irradiation time of 5 h, the grafting rate can reach 25.83%. Scanning electron microscope (SEM) and X-ray photoelectron spectrometer (XPS) are used to confirm the successful grafting of CMAs onto nonwoven PA materials. The stability and fastness test was used to show that PA-CMAs have good stability with acid, alkali, organic solvent resistance, and rubbing resistance. The contrast test indicated that the moisture absorption and permeability of PA-CMAs were better than those of nonwoven polyamide/polyurethane (PA/PU), which is a synthetic leather-based material considered as one of the mainstream products. In addition, PA-CMAs maintained the original softness and elastoplasticity of PA.

quote

GB/T 7714-2015 [1] Na Xu, Yanmei Xing, Xuechuan Wang. ACS Applied Polymer Materials, 2022(4). DOI:10.1021/acsapm.1c01343.
MLA [1] Na Xu, et al., ACS Applied Polymer Materials, no. 4, 2022, https://doi.org/10.1021/acsapm.1c01343.
APA [1] Na Xu, Yanmei Xing, & Xuechuan Wang. (2022). ACS Applied Polymer Materials(4). https://doi.org/10.1021/acsapm.1c01343
IEEE [1] Na Xu, Yanmei Xing, and Xuechuan Wang, ACS Applied Polymer Materials, no. 4, 2022, doi: 10.1021/acsapm.1c01343. keywords: {waste leather collagen;collagen microspheres;nonwoven polyamide fibers;moisture absorption and permeability;Show More}