daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Ultrabroad Dynamic All-Solid-State Radiation Dose Detector Based on a 0D Cs3Cu2I5 Perovskite-Like Single Crystal Ultrabroad Dynamic All-Solid-State Radiation Dose Detector Based on a 0D Cs3Cu2I5 Perovskite-Like Single Crystal AITranslate

Xi’an Jiaotong University;Northwest Institute of Nuclear Technology; Xi’an Jiaotong University; Beijing Normal University;Northwest Institute of Nuclear Technology;Shanghai Institute of Ceramics; Sun Yat-Sen University;Institute of Microelectronics;Shanghai Institute of Ceramics;Shanghai Institute of Ceramics; Sun Yat-Sen University; Xi’an Jiaotong University
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Radiation dose detectors based on a gas-filled detecting mode play an important role in cancer radiation therapy, nuclear accident early warning, and radiation protection but still suffer from frequent air density corrections, a high working voltage, and a long stability time. Therefore, to tackle these issues, the development of high-performance all-solid-state radiation dose detectors is urgently needed. Here, we demonstrated a prototype of a highly sensitive all-solid-state radiation dose detector based on a highly efficient Cs3Cu2I5 perovskite-like single crystal and a Si photodetector with a heterojunction structure. The Cs3Cu2I5-based detector exhibits an ultrabroad dynamic range of 11.45 mGy·h–1 to 107.3 Gy·h–1, covering nearly 5 orders of magnitude for γ-ray with the upper limit being 100 times higher than that of Cs3Cu2I nanocrystal of 0.846 Gy·h–1 and the detection limit approaching the lower limit of the radiotherapy level (10 mGy·h–1). Moreover, it has an outstanding linear response with a linear correlation coefficient (R2) of 0.9999 for the X/γ-ray incident dose rate and a good repeatable response deviation of less than 0.3% for γ-rays, which is comparable to classical ionization chamber detectors. This work opens a horizon of developing ultrabroad dynamic, highly sensitive, and low-power consumption all-solid-state radiation dose detectors based on perovskite-like single-crystal scintillators.

KeyWords AITranslate

perovskitelike Cs3Cu2I5 single crystal radiation dose X/γray detector dynamic range
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.3c01256

Chinese Library Classification Number:

Citation Information:

Radiation dose detectors based on a gas-filled detecting mode play an important role in cancer radiation therapy, nuclear accident early warning, and radiation protection but still suffer from frequent air density corrections, a high working voltage, and a long stability time. Therefore, to tackle these issues, the development of high-performance all-solid-state radiation dose detectors is urgently needed. Here, we demonstrated a prototype of a highly sensitive all-solid-state radiation dose detector based on a highly efficient Cs3Cu2I5 perovskite-like single crystal and a Si photodetector with a heterojunction structure. The Cs3Cu2I5-based detector exhibits an ultrabroad dynamic range of 11.45 mGy·h–1 to 107.3 Gy·h–1, covering nearly 5 orders of magnitude for γ-ray with the upper limit being 100 times higher than that of Cs3Cu2I nanocrystal of 0.846 Gy·h–1 and the detection limit approaching the lower limit of the radiotherapy level (10 mGy·h–1). Moreover, it has an outstanding linear response with a linear correlation coefficient (R2) of 0.9999 for the X/γ-ray incident dose rate and a good repeatable response deviation of less than 0.3% for γ-rays, which is comparable to classical ionization chamber detectors. This work opens a horizon of developing ultrabroad dynamic, highly sensitive, and low-power consumption all-solid-state radiation dose detectors based on perovskite-like single-crystal scintillators.

quote

GB/T 7714-2015 [1] Xiaojing Song, Linyue Liu, Pengying Wan, et al. ACS Applied Electronic Materials, 2023(5). DOI:10.1021/acsaelm.3c01256.
MLA [1] Xiaojing Song, et al., ACS Applied Electronic Materials, no. 5, 2023, https://doi.org/10.1021/acsaelm.3c01256.
APA [1] Xiaojing Song, Linyue Liu, Pengying Wan, Xiao Ouyang, Tao Bai, Qian Wang, Runlong Gao, Rui Jia, Qiang Gao, Yuntao Wu, Wei Zheng, & Xiaoping Ouyang. (2023). ACS Applied Electronic Materials(5). https://doi.org/10.1021/acsaelm.3c01256
IEEE [1] Xiaojing Song, Linyue Liu, Pengying Wan, Xiao Ouyang, Tao Bai, Qian Wang, Runlong Gao, Rui Jia, Qiang Gao, Yuntao Wu, Wei Zheng, and Xiaoping Ouyang, ACS Applied Electronic Materials, no. 5, 2023, doi: 10.1021/acsaelm.3c01256. keywords: {perovskitelike Cs3Cu2I5 single crystal radiation dose X/γray detector dynamic range}