daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Flexible PDMS Composite Electrodes with Boronic Acid-Modified Carbon Dots for Surface Electrophysiological Signal Recording Flexible PDMS Composite Electrodes with Boronic Acid-Modified Carbon Dots for Surface Electrophysiological Signal Recording AITranslate

American University of Sharjah; American University of Sharjah; American University of Sharjah; American University of Sharjah
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Conventional surface electrodes are composed of rigid metals such as Ag/AgCl that are not only harsh to the skin but also irritating if used as wet electrodes. Furthermore, rigid, inflexible surface electrodes can cause patient discomfort when used for the long term. To reduce the mechanical mismatch, flexible alternatives to metal electrodes are needed. This study reports the development of highly flexible composite electrodes fabricated from the conductive dopant boronic acid-modified carbon dots embedded in a polydimethylsiloxane matrix. The electrodes were characterized for their structural, electrochemical, and mechanical characteristics and for their ability to record electrophysiological signals. Furthermore, the composition of these electrodes was varied systematically to obtain the optimal electrochemical and mechanical properties. The best-performing electrode, composed of 10% boronic acid-modified carbon dots, 16% glycerol, and 74% polydimethylsiloxane (8:1 elastomer to curing agent), had a smooth surface, a promising conductivity of 9.62 × 10–3 S/cm, an impedance of 964 kΩ at 1 kHz, and a charge storage capacity of 21.4 μC/cm2. This electrode had a Young’s modulus of 0.0545 MPa, which is compatible with biological tissues’ elasticity. The fabricated electrodes recorded high-quality electrocardiography signals with a promising signal-to-noise ratio (SNR) of 36.75 dB that is comparable to that of commercial Ag/AgCl, which had an SNR of 39.98 dB. A similarly good performance was observed with electromyography. Furthermore, the developed flexible surface electrodes maintained their ability to record high-quality ECG and EMG over a period of 3 weeks.

KeyWords AITranslate

boronic acid carbon dots PDMS flexible electrodes surface electrodes electrocardiography electromyography
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.3c01617

Chinese Library Classification Number:

Citation Information:

Conventional surface electrodes are composed of rigid metals such as Ag/AgCl that are not only harsh to the skin but also irritating if used as wet electrodes. Furthermore, rigid, inflexible surface electrodes can cause patient discomfort when used for the long term. To reduce the mechanical mismatch, flexible alternatives to metal electrodes are needed. This study reports the development of highly flexible composite electrodes fabricated from the conductive dopant boronic acid-modified carbon dots embedded in a polydimethylsiloxane matrix. The electrodes were characterized for their structural, electrochemical, and mechanical characteristics and for their ability to record electrophysiological signals. Furthermore, the composition of these electrodes was varied systematically to obtain the optimal electrochemical and mechanical properties. The best-performing electrode, composed of 10% boronic acid-modified carbon dots, 16% glycerol, and 74% polydimethylsiloxane (8:1 elastomer to curing agent), had a smooth surface, a promising conductivity of 9.62 × 10–3 S/cm, an impedance of 964 kΩ at 1 kHz, and a charge storage capacity of 21.4 μC/cm2. This electrode had a Young’s modulus of 0.0545 MPa, which is compatible with biological tissues’ elasticity. The fabricated electrodes recorded high-quality electrocardiography signals with a promising signal-to-noise ratio (SNR) of 36.75 dB that is comparable to that of commercial Ag/AgCl, which had an SNR of 39.98 dB. A similarly good performance was observed with electromyography. Furthermore, the developed flexible surface electrodes maintained their ability to record high-quality ECG and EMG over a period of 3 weeks.

quote

GB/T 7714-2015 [1] Amaal Abdulraqeb Ali, Mohammad H. AlSayah, Amani AlOthman, et al. ACS Applied Electronic Materials, 2024(6). DOI:10.1021/acsaelm.3c01617.
MLA [1] Amaal Abdulraqeb Ali, et al., ACS Applied Electronic Materials, no. 6, 2024, https://doi.org/10.1021/acsaelm.3c01617.
APA [1] Amaal Abdulraqeb Ali, Mohammad H. AlSayah, Amani AlOthman, & Hasan AlNashash. (2024). ACS Applied Electronic Materials(6). https://doi.org/10.1021/acsaelm.3c01617
IEEE [1] Amaal Abdulraqeb Ali, Mohammad H. AlSayah, Amani AlOthman, and Hasan AlNashash, ACS Applied Electronic Materials, no. 6, 2024, doi: 10.1021/acsaelm.3c01617. keywords: {boronic acid carbon dots PDMS flexible electrodes surface electrodes electrocardiography electromyography}