daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

MXene-Integrated Single-Stranded Carbon Yarn-Based Wearable Sensor Patch for On-Site Monitoring of Dopamine MXene-Integrated Single-Stranded Carbon Yarn-Based Wearable Sensor Patch for On-Site Monitoring of Dopamine AITranslate

Indian Institute of Technology Palakkad; Indian Institute of Technology Palakkad; Indian Institute of Technology Palakkad
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

The demand for noninvasive wearable sensors for on-site monitoring has surged, particularly in the realm of personalized healthcare. This study introduces a pioneering approach employing a MXene-integrated single-stranded carbon yarn-based sensor patch utilizing a minimalist three-thread electrode setup for real-time monitoring of dopamine levels from artificial human sweat. The ability to immediately sew, weave, or stitch sensor platforms onto any type of clothing makes wearable thread-based sensor patches extremely promising, and it can be positioned in close proximity to the skin. Flexible conductive carbon yarn (CCY) was modified by Ti3C2Tx MXene by a facile dip-coating method which was used as sensing electrodes. Leveraging MXene’s high surface area and exceptional conductivity, the sensor’s architecture achieved heightened sensitivity and selectivity in dopamine detection and reproducibility in a broad linear range of 1 nM–1 μM with a detection limit of 316 pM, along with real sample tests showing the promise of this platform for real-time physiological monitoring of human performance/fitness under stress as well as diagnostic monitoring through sweat analysis. The three-thread electrode configuration, strategically embedded within the patch, ensures ease of use and comfortable, noninvasive on-body application, offering a promising avenue for continuous, real-time monitoring of dopamine levels in individuals with neurological disorders or relevant medical conditions. This study highlights the potential of MXene-integrated wearable sensor patches with a minimalist electrode setup, advancing the field of wearable sensing technologies for personalized healthcare and point-of-care diagnostics.

KeyWords AITranslate

conducting carbon yarn disposable electrodes bandaid sensor Ti3C2Tx MXene dopamine wearable sensor
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.3c01668

Chinese Library Classification Number:

Citation Information:

The demand for noninvasive wearable sensors for on-site monitoring has surged, particularly in the realm of personalized healthcare. This study introduces a pioneering approach employing a MXene-integrated single-stranded carbon yarn-based sensor patch utilizing a minimalist three-thread electrode setup for real-time monitoring of dopamine levels from artificial human sweat. The ability to immediately sew, weave, or stitch sensor platforms onto any type of clothing makes wearable thread-based sensor patches extremely promising, and it can be positioned in close proximity to the skin. Flexible conductive carbon yarn (CCY) was modified by Ti3C2Tx MXene by a facile dip-coating method which was used as sensing electrodes. Leveraging MXene’s high surface area and exceptional conductivity, the sensor’s architecture achieved heightened sensitivity and selectivity in dopamine detection and reproducibility in a broad linear range of 1 nM–1 μM with a detection limit of 316 pM, along with real sample tests showing the promise of this platform for real-time physiological monitoring of human performance/fitness under stress as well as diagnostic monitoring through sweat analysis. The three-thread electrode configuration, strategically embedded within the patch, ensures ease of use and comfortable, noninvasive on-body application, offering a promising avenue for continuous, real-time monitoring of dopamine levels in individuals with neurological disorders or relevant medical conditions. This study highlights the potential of MXene-integrated wearable sensor patches with a minimalist electrode setup, advancing the field of wearable sensing technologies for personalized healthcare and point-of-care diagnostics.

quote

GB/T 7714-2015 [1] Menon Ankitha, Fathima Shamsheera, P Abdul Rasheed. ACS Applied Electronic Materials, 2024(6). DOI:10.1021/acsaelm.3c01668.
MLA [1] Menon Ankitha, et al., ACS Applied Electronic Materials, no. 6, 2024, https://doi.org/10.1021/acsaelm.3c01668.
APA [1] Menon Ankitha, Fathima Shamsheera, & P Abdul Rasheed. (2024). ACS Applied Electronic Materials(6). https://doi.org/10.1021/acsaelm.3c01668
IEEE [1] Menon Ankitha, Fathima Shamsheera, and P Abdul Rasheed, ACS Applied Electronic Materials, no. 6, 2024, doi: 10.1021/acsaelm.3c01668. keywords: {conducting carbon yarn disposable electrodes bandaid sensor Ti3C2Tx MXene dopamine wearable sensor}