Determination of Nitrogen Content in Uranium-Niobium Alloy AITranslate
Abstract AITranslate
Nitrogen content in uranium-niobium alloy was determined by pulse melting heat conduction with LECO TC-436 analyzer. The effect factors such as analysis power, flux types, sample weight on determination results were discussed and the optimum analytical conditions were identified. The results show that the RSD for determination of nitrogen content in uranium-niobium alloy is less than 15 %, and the recovery of the nitrogen is 84%~93%, detection lower limit is 20μg/g, which is basically consistent with that by Kjeldahl for the determination of the nitrogen content.
KeyWords AITranslate
1伯克J J.铀合金物理冶金【M】.北京:原子能出版社,1983.
2钟华.惰气熔融-热导法测定氮化铬铁中氮[J].冶金分析,2010,31(3):64-67. 被引量:10
3耿小颖,张克顺,杨春晟,程旭.脉冲加热-红外吸收、热导法测定粉末高温合金中氧、氮[J].分析试验室,2009,28(B05):303-306. 被引量:7
4孙金库,秦毅,王树安.红外吸收法和热导法测定铀钼合金中氧和氮[J].冶金分析,2010,31(5):6-8. 被引量:9
5张克顺.脉冲加热-热导法测定钛及钛合金中氮的研究[J].冶金分析,1999,19(5):24-26. 被引量:6
1赵飞,杨军红,翟通德,王芳.惰气熔融-红外/热导法测定铪中氧和氮含量[J].材料研究与应用,2016,10(4):283-286. 被引量:2
2武红英,李英秋,卞敏.光纤光度计测定铀及铀铌合金中氮含量[J].核化学与放射化学,2012,34(2):124-128. 被引量:1
3武红英,李英秋,吴梅,刘钧.离子选择电极法测定铀及铀铌合金中的微量氮[J].核化学与放射化学,2011,33(2):96-100. 被引量:1
4郇枚.钢中氧氮的测定[J].冶金分析,2004(z1):423-424. 被引量:2
5伏晓国,刘柯钊,汪小琳,柏朝茂,赵正平.铀铌合金在O_2气氛中氧化初期的XPS研究[J].核技术,2001,24(10):848-852. 被引量:8
6蒋亚芳.TCH600氧氮氢仪测定WC-Ni_3Al中氧量[J].有色金属文摘,2016,31(1):182-183. 被引量:1
7徐本平,李晖.钒氮合金中的高含量氮的测定[J].冶金分析,2004(z1):358-360. 被引量:2
8王松.红外吸收-热导法测定金属铬中的氧、氮含量[J].大型铸锻件,2013(5):42-44. 被引量:4
9程美洁.惰气熔融-热导法测定碳化铬粉末中的氮含量[J].当代化工,2015,44(5):1191-1192.
10杨帆.惰气熔融-热导法测定氮化硅铁中氮[J].冶金分析,2008,28(5):78-80. 被引量:9
Basic Information:
DOI:
Chinese Library Classification Number:O655.11[理学—分析化学]
Citation Information:
Nitrogen content in uranium-niobium alloy was determined by pulse melting heat conduction with LECO TC-436 analyzer. The effect factors such as analysis power, flux types, sample weight on determination results were discussed and the optimum analytical conditions were identified. The results show that the RSD for determination of nitrogen content in uranium-niobium alloy is less than 15 %, and the recovery of the nitrogen is 84%~93%, detection lower limit is 20μg/g, which is basically consistent with that by Kjeldahl for the determination of the nitrogen content.
quote
| GB/T 7714-2015 | [1] WU Hong-ying, BIAN Min, ZHAO Yun-hui, et al. Determination of Nitrogen Content in Uranium-Niobium Alloy[J]. Rare Metals and Cemented Carbides, 2011(4): 66-69. |
| MLA | [1] WU Hong-ying, et al., "Determination of Nitrogen Content in Uranium-Niobium Alloy." Rare Metals and Cemented Carbides, no. 4, 2011, pp. 66-69. |
| APA | [1] WU Hong-ying, BIAN Min, ZHAO Yun-hui, & LI Ying-qiu. (2011). Determination of Nitrogen Content in Uranium-Niobium Alloy. Rare Metals and Cemented Carbides(4), 66-69. |
| IEEE | [1] WU Hong-ying, BIAN Min, ZHAO Yun-hui, and LI Ying-qiu, "Determination of Nitrogen Content in Uranium-Niobium Alloy," Rare Metals and Cemented Carbides, no. 4, pp. 66-69, 2011. keywords: {uranium-niobium alloy;pulse melting heat conduction;oxygen and nitrogen analyzer;oxygen andnitrogen determination} |