Application of Contact Filtration Process into Effluent Treatment in the Chemical Smelter AITranslate
Abstract AITranslate
By depth filtration of suspended material in effluent after treatment using contact filtration process,the total Zn and Cd concentration in the effluent discharge can be dropped to 1.50 mg/L and 0.05 mg/L respectively and the availability of effluent after treatment can be improved from 10 % to 60 %. Effluent discharge coefficient is 7- 8 m^3 per ton of production. Effluent discharge can meet the environmental protection requirements of the government.
KeyWords AITranslate
1李秀敏,孙力平,杨聪和,李亮.高速过滤技术处理再生污水的试验研究[J].天津城市建设学院学报,2005,11(1):29-32. 被引量:6
2王健,欧阳剑,曹伟新,闫东晗,李静毅.法国均质滤料滤池的设计特点[J].中国给水排水,2006,22(20):45-48. 被引量:3
3唐朝春,李代云,喻恒,刘汉栋.单层砂滤料截污分布与反冲洗效果研究[J].水处理技术,2006,32(5):33-35. 被引量:2
1朱文英.接触过滤技术在冶金化工污水处理中的应用研究[J].世界有色金属,2021(5):7-8. 被引量:1
1周俊.试论脱氮工艺在化工污水处理中的应用[J].皮革制作与环保科技,2021,2(13):95-96. 被引量:1
1颜敏.复合混凝剂在冶金化工污水处理中的应用[J].山西冶金,2013,36(2):61-63. 被引量:1
2李林.探析接触过滤技术在冶金化工污水处理中的应用[J].化工管理,2014,0(24):207-208. 被引量:2
3李树存,张玉林,王伟.中水回用工程在住宅小区的应用[J].河北建筑科技学院学报,2002,19(2):19-20. 被引量:4
4余志,范跃华.涡流电凝聚-气浮-接触过滤组合工艺处理洗车废水的试验研究[J].水处理信息报导,2008(5):56-56.
5杨卫芬,银燕,魏玉香,陈魁.霾天气下南京PM_(2.5)中金属元素污染特征及来源分析[J].中国环境科学,2010,30(1):12-17. 被引量:128
6余海静,张霞,王现丽,吴俊峰.UASB+SBR+接触过滤工艺处理皮革废水运行效果分析[J].工业水处理,2010,30(11):86-88.
7刘成,李俊林,陈卫,陈彬,邱斌.接触过滤/磁性树脂工艺对二沉池出水的处理效能[J].中国给水排水,2011,27(9):13-15. 被引量:5
8余志,范跃华,王仕汇,陈威.涡流电凝聚-气浮-接触过滤组合工艺处理洗车废水的试验研究[J].工业用水与废水,2008,39(2):42-45. 被引量:2
9陈莹,陈鹏.逆向流气浮+生物接触过滤工艺初探[J].天津市政工程,1996,8(3):19-22.
10刘立,胡辉,李娴,黄焕彦,蔡勋江,张国斐.东莞市PM_1中重金属元素的污染特征及来源解析[J].环境科学学报,2014,34(2):303-309. 被引量:14
Basic Information:
DOI:
Chinese Library Classification Number:X703.1[环境科学与工程—环境工程]
Citation Information:
By depth filtration of suspended material in effluent after treatment using contact filtration process,the total Zn and Cd concentration in the effluent discharge can be dropped to 1.50 mg/L and 0.05 mg/L respectively and the availability of effluent after treatment can be improved from 10 % to 60 %. Effluent discharge coefficient is 7- 8 m^3 per ton of production. Effluent discharge can meet the environmental protection requirements of the government.
quote
| GB/T 7714-2015 | [1] YAN Min. Application of Contact Filtration Process into Effluent Treatment in the Chemical Smelter[J]. Rare Metals and Cemented Carbides, 2007(2): 28-30. |
| MLA | [1] YAN Min. "Application of Contact Filtration Process into Effluent Treatment in the Chemical Smelter." Rare Metals and Cemented Carbides, no. 2, 2007, pp. 28-30. |
| APA | [1] YAN Min. (2007). Application of Contact Filtration Process into Effluent Treatment in the Chemical Smelter. Rare Metals and Cemented Carbides(2), 28-30. |
| IEEE | [1] YAN Min, "Application of Contact Filtration Process into Effluent Treatment in the Chemical Smelter," Rare Metals and Cemented Carbides, no. 2, pp. 28-30, 2007. keywords: {contact filtration;chemical smelter;effluent treatment;suspended material;environmental protection} |