daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Self-Enhanced Electrochemiluminescence Microreactors Based on Bimetallic Porphyrin Covalent Organic Frameworks for MicroRNA Detection AITranslate

Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials;Shandong Provincial Key Laboratory of Preparation and Measurement of Building Materials
AITranslate
Publisher: Youke Publish Co., Ltd.
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Controlling the intermolecular charge transfer between co-reactants and emitters represents a promising strategy for elucidating the luminescent mechanism and enhancing the efficiency of electrochemiluminescence(ECL)systems.Herein,a self-enhanced ECL microreactor was prepared by bimetallic Zn-/Co-porphyrin covalent organic framework(COFZn/CoP-Ph@MWCNTs),in which co-reaction accelerators(cobalt porphyrin)and luminophores(zinc porphyrin)were precisely woven into the COFs skeleton via covalent bonds.Owing to the unique topological structure,the rational arrangement of coreaction accelerators and luminophores in a spatially confined environment effectively controlled the intermolecular charge transfer.And the spatially restricted environment formed by the COFZn/CoP-Ph@MWCNTs microreactor avoided the problem of disordered diffusion of active intermediates,leading to an enhanced ECL response.Thanks to the synergistic impacts of the factors above,the ECL intensity of the bimetallic COFZn/CoP-Ph@MWCNTs was 10.2-folds stronger than the zinc porphyrin monomer.Therefore,the self-enhanced ECL sensor was constructed for miRNA-155 detection via an“on-off”ECL quenching mechanism and a cycling amplification strategy,displayed a broad linear range(0.10 pM–10μM)and a low limit of detection(0.51 fM).In brief,studying the programmable structures and tunable electronic paths of high-performance COF materials would provide good access for the engineering self-enhanced ECL system and the construction of ultrasensitive sensors.

KeyWords AITranslate

Electrochemiluminescence Bimetallic compounds Covalent organic framework MicroRNA Porphyrin Self-enhanced
No data

Basic Information:

DOI:

Chinese Library Classification Number:O657.1[理学]

Citation Information:

Controlling the intermolecular charge transfer between co-reactants and emitters represents a promising strategy for elucidating the luminescent mechanism and enhancing the efficiency of electrochemiluminescence(ECL)systems.Herein,a self-enhanced ECL microreactor was prepared by bimetallic Zn-/Co-porphyrin covalent organic framework(COFZn/CoP-Ph@MWCNTs),in which co-reaction accelerators(cobalt porphyrin)and luminophores(zinc porphyrin)were precisely woven into the COFs skeleton via covalent bonds.Owing to the unique topological structure,the rational arrangement of coreaction accelerators and luminophores in a spatially confined environment effectively controlled the intermolecular charge transfer.And the spatially restricted environment formed by the COFZn/CoP-Ph@MWCNTs microreactor avoided the problem of disordered diffusion of active intermediates,leading to an enhanced ECL response.Thanks to the synergistic impacts of the factors above,the ECL intensity of the bimetallic COFZn/CoP-Ph@MWCNTs was 10.2-folds stronger than the zinc porphyrin monomer.Therefore,the self-enhanced ECL sensor was constructed for miRNA-155 detection via an“on-off”ECL quenching mechanism and a cycling amplification strategy,displayed a broad linear range(0.10 pM–10μM)and a low limit of detection(0.51 fM).In brief,studying the programmable structures and tunable electronic paths of high-performance COF materials would provide good access for the engineering self-enhanced ECL system and the construction of ultrasensitive sensors.

quote

GB/T 7714-2015 [1] Lina Zhang, Wenqing Gao, Liying Zhang, et al. Journal of Analysis and Testing, 2025(4): 635-645.
MLA [1] Lina Zhang, et al., Journal of Analysis and Testing, no. 4, 2025, pp. 635-645.
APA [1] Lina Zhang, Wenqing Gao, Liying Zhang, Xiaojie Ma, Yan Zhang, Peihua Zhu, & Jinghua Yu. (2025). Journal of Analysis and Testing(4), 635-645.
IEEE [1] Lina Zhang, Wenqing Gao, Liying Zhang, Xiaojie Ma, Yan Zhang, Peihua Zhu, and Jinghua Yu, Journal of Analysis and Testing, no. 4, pp. 635-645, 2025.