daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Ion Sensitivity of Hygroscopic Insulator Field Effect Transistors Ion Sensitivity of Hygroscopic Insulator Field Effect Transistors AITranslate

Queensland University of Technology (QUT); Queensland University of Technology (QUT)
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Given the many and varied roles of ions in living organisms, biocompatible organic ion sensors are a matter of considerable interest. In this work, simple, low-voltage, solid-state hygroscopic insulator field effect transistors (HIFETs) have been tested to characterize their ion-sensitive properties. Two biologically relevant salt solutions, sodium chloride (NaCl) and potassium chloride (KCl), were tested. To assess pH sensitivity, solutions of hydrochloric acid (HCl) and sodium hydroxide (NaOH) were also tested. The salts and acidic solutions caused similar, concentration-dependent changes in HIFET performance from 10 mM to 1 M, consistent with an increase in ion concentration in the hygroscopic insulator, increasing device capacitance. By contrast, basic solutions caused an overall decrease in device performance, consistent with a net removal of ions due to acid–base reactions between the insulator and the analyte. These results show that HIFETs exhibit promising sensitivity to a range of ions and can therefore serve as platforms for future ion-selective devices.

KeyWords AITranslate

OTFT hygroscopic insulator sensors ions sodium potassium chloride pH
No data

Basic Information:

DOI:https://doi.org/10.1021/acsaelm.1c01205

Chinese Library Classification Number:

Citation Information:

Given the many and varied roles of ions in living organisms, biocompatible organic ion sensors are a matter of considerable interest. In this work, simple, low-voltage, solid-state hygroscopic insulator field effect transistors (HIFETs) have been tested to characterize their ion-sensitive properties. Two biologically relevant salt solutions, sodium chloride (NaCl) and potassium chloride (KCl), were tested. To assess pH sensitivity, solutions of hydrochloric acid (HCl) and sodium hydroxide (NaOH) were also tested. The salts and acidic solutions caused similar, concentration-dependent changes in HIFET performance from 10 mM to 1 M, consistent with an increase in ion concentration in the hygroscopic insulator, increasing device capacitance. By contrast, basic solutions caused an overall decrease in device performance, consistent with a net removal of ions due to acid–base reactions between the insulator and the analyte. These results show that HIFETs exhibit promising sensitivity to a range of ions and can therefore serve as platforms for future ion-selective devices.

quote

GB/T 7714-2015 [1] Joshua N. Arthur, Soniya D. Yambem. ACS Applied Electronic Materials, 2022(4). DOI:10.1021/acsaelm.1c01205.
MLA [1] Joshua N. Arthur, and Soniya D. Yambem. ACS Applied Electronic Materials, no. 4, 2022, https://doi.org/10.1021/acsaelm.1c01205.
APA [1] Joshua N. Arthur, & Soniya D. Yambem. (2022). ACS Applied Electronic Materials(4). https://doi.org/10.1021/acsaelm.1c01205
IEEE [1] Joshua N. Arthur and Soniya D. Yambem, ACS Applied Electronic Materials, no. 4, 2022, doi: 10.1021/acsaelm.1c01205. keywords: {OTFT hygroscopic insulator sensors ions sodium potassium chloride pH}