daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Microneedles with Recessed Microcavities for Electrochemical Sensing in Dermal Interstitial Fluid AITranslate

Monash University; Monash University
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Transdermal electrochemical sensors based on microneedle (MN) or MN array technology are the next frontier of personalized wearable devices in health monitoring and diagnostics. The performance of transdermal sensors is impacted mainly by damage or deformation of the sensing layer located on the MN surface, which usually occurs due to friction caused between the MN surface and skin tissue. In this work, we report the development of a 4 × 4 polymeric MN array (PMNA) with an individual MN height of ∼720 μm and integrated conductive recessed microcavities (MC) on the MNs surface to protect the sensing layer during insertion and removal from the skin. Characterization and proof-of-concept experiments on porcine skin reveal that PMNA/MC-based platforms retain their functionality and sensitivity of 2.36 ± 0.06 nA mM–1 even after multiple skin applications. Three-dimensional nanostructuring of MNA hence provides alternative solutions to the critical issues of maintaining performance upon insertion into skin. This approach holds great potential in advancing transdermal sensing technology and affording reliable, cost-effective, and clinically adequate sensing devices.

KeyWords AITranslate

No data

Basic Information:

DOI:https://doi.org/10.1021/acsmaterialslett.3c00441

Chinese Library Classification Number:

Citation Information:

Transdermal electrochemical sensors based on microneedle (MN) or MN array technology are the next frontier of personalized wearable devices in health monitoring and diagnostics. The performance of transdermal sensors is impacted mainly by damage or deformation of the sensing layer located on the MN surface, which usually occurs due to friction caused between the MN surface and skin tissue. In this work, we report the development of a 4 × 4 polymeric MN array (PMNA) with an individual MN height of ∼720 μm and integrated conductive recessed microcavities (MC) on the MNs surface to protect the sensing layer during insertion and removal from the skin. Characterization and proof-of-concept experiments on porcine skin reveal that PMNA/MC-based platforms retain their functionality and sensitivity of 2.36 ± 0.06 nA mM–1 even after multiple skin applications. Three-dimensional nanostructuring of MNA hence provides alternative solutions to the critical issues of maintaining performance upon insertion into skin. This approach holds great potential in advancing transdermal sensing technology and affording reliable, cost-effective, and clinically adequate sensing devices.

quote

GB/T 7714-2015 [1] Muamer Dervisevic, Nicolas H. Voelcker. ACS Materials Letters, 2023(5). DOI:10.1021/acsmaterialslett.3c00441.
MLA [1] Muamer Dervisevic, and Nicolas H. Voelcker. ACS Materials Letters, no. 5, 2023, https://doi.org/10.1021/acsmaterialslett.3c00441.
APA [1] Muamer Dervisevic, & Nicolas H. Voelcker. (2023). ACS Materials Letters(5). https://doi.org/10.1021/acsmaterialslett.3c00441
IEEE [1] Muamer Dervisevic and Nicolas H. Voelcker, ACS Materials Letters, no. 5, 2023, doi: 10.1021/acsmaterialslett.3c00441.