daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Binding Studies of Cationic Conjugated Polymers and DNA for Label-Free Fluorescent Biosensors AITranslate

University of Science and Technology Beijing; 200 University Avenue West; 200 University Avenue West; University of Science and Technology Beijing; University of Science and Technology Beijing; 200 University Avenue West
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

Cationic conjugated polymers (CCPs), especially polythiophene, have been extensively used as probes for developing DNA and aptamer-based biosensors. Although many interesting applications have been achieved, a fundamental understanding of this system remains quite limited. In this work, we performed systematic binding assays to understand the interactions between poly(3-(3′-N,N,N-triethylamino-1′-propyloxy)-4-methyl-2,5-thiophene) (PMNT) and DNA. The fluorescence of PMNT at 530 nm initially decreased and then a peak at 580 nm emerged after binding with single-stranded DNA (ssDNA). The binding force between PMNT and DNA was dominated by electrostatic interactions at first and then DNA base-mediated interactions also became important. Since the bases in double-stranded DNA (dsDNA) were shielded, their fluorescence changes were quite different. To best differentiate ssDNA and dsDNA, the optimal pH was between 6 and 8, and the optimal NaCl concentration was around 0.3 M. Moreover, by changing the sequence and length of ssDNA, poly-T had the largest fluorescence shift and poly-A had the smallest change. Under the optimized conditions, the PMNT-based biosensor had a detection limit of 1 nM DNA, which was similar to the SYBR Green I-based assay.

KeyWords AITranslate

cationic conjugated polymers DNA detection biosensors aptamers fluorescence
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.2c00986

Chinese Library Classification Number:

Citation Information:

Cationic conjugated polymers (CCPs), especially polythiophene, have been extensively used as probes for developing DNA and aptamer-based biosensors. Although many interesting applications have been achieved, a fundamental understanding of this system remains quite limited. In this work, we performed systematic binding assays to understand the interactions between poly(3-(3′-N,N,N-triethylamino-1′-propyloxy)-4-methyl-2,5-thiophene) (PMNT) and DNA. The fluorescence of PMNT at 530 nm initially decreased and then a peak at 580 nm emerged after binding with single-stranded DNA (ssDNA). The binding force between PMNT and DNA was dominated by electrostatic interactions at first and then DNA base-mediated interactions also became important. Since the bases in double-stranded DNA (dsDNA) were shielded, their fluorescence changes were quite different. To best differentiate ssDNA and dsDNA, the optimal pH was between 6 and 8, and the optimal NaCl concentration was around 0.3 M. Moreover, by changing the sequence and length of ssDNA, poly-T had the largest fluorescence shift and poly-A had the smallest change. Under the optimized conditions, the PMNT-based biosensor had a detection limit of 1 nM DNA, which was similar to the SYBR Green I-based assay.

quote

GB/T 7714-2015 [1] Pengbo Zhang, Chang Lu, Chenqi Niu, et al. ACS Applied Polymer Materials, 2022(4). DOI:10.1021/acsapm.2c00986.
MLA [1] Pengbo Zhang, et al., ACS Applied Polymer Materials, no. 4, 2022, https://doi.org/10.1021/acsapm.2c00986.
APA [1] Pengbo Zhang, Chang Lu, Chenqi Niu, Xiaoyu Wang, Zhengping Li, & Juewen Liu. (2022). ACS Applied Polymer Materials(4). https://doi.org/10.1021/acsapm.2c00986
IEEE [1] Pengbo Zhang, Chang Lu, Chenqi Niu, Xiaoyu Wang, Zhengping Li, and Juewen Liu, ACS Applied Polymer Materials, no. 4, 2022, doi: 10.1021/acsapm.2c00986. keywords: {cationic conjugated polymers;DNA detection;biosensors;aptamers;fluorescence}