daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Polyfluorene-Based Bioconjugates for Selective Detection of Ferritin in Normal and Cancer Human Blood Serums AITranslate

Indian Institute of Technology Guwahati; Indian Institute of Technology Guwahati; Indian Institute of Technology Guwahati;Department of ENT, Sanjevani Hospital; Indian Institute of Technology Guwahati
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

A new highly conjugated polymer–bioconjugate poly[9,9-bis(6′-adenine) hexyl)fluorene-co-4,7-(2,1,3 benzothiadiazole)] (PFBT-A) is developed using the well-known Pd(PPh3)4-catalyzed Suzuki cross-coupling polymerization reaction with a simple purification method. PFBT-A showed excellent sensitivity toward the iron containing metalloprotein and the well-known cancer biomarker ferritin with a detection limit as low as 0.164 nM (i.e., 71.05 ng/mL), which is much below the ferritin level observed in the blood serum of cancer patients. Detailed mechanistic study confirmed the presence of static ground state complexation and electrostatic interaction between the probe and the analyte, leading to quenching in fluorescence intensity of the probe. Real-time applications with the probe were performed in the unspiked serum samples of two normal people and two cancer patients (carcinoma valva and chronic myeloid leukemia) with significantly high ferritin content. Further analysis of PFBT-A in spiked normal blood serum samples showed good recoveries in the range of 102–102.5% with relative standard deviations (RSDs) within 1.07–1.16%, confirming the reliability and practical applicability of PFBT-A for ferritin detection in human blood serum. In the case of cancer blood serums, the recoveries were high, in the range of 105–109%, showing a high level of ferritin in cancer patients.

KeyWords AITranslate

conjugated polymer−bioconjugate ferritin cancer biomarker biosensing blood serum fluorescence
No data

Basic Information:

DOI:https://doi.org/10.1021/acsapm.8b00016

Chinese Library Classification Number:

Citation Information:

A new highly conjugated polymer–bioconjugate poly[9,9-bis(6′-adenine) hexyl)fluorene-co-4,7-(2,1,3 benzothiadiazole)] (PFBT-A) is developed using the well-known Pd(PPh3)4-catalyzed Suzuki cross-coupling polymerization reaction with a simple purification method. PFBT-A showed excellent sensitivity toward the iron containing metalloprotein and the well-known cancer biomarker ferritin with a detection limit as low as 0.164 nM (i.e., 71.05 ng/mL), which is much below the ferritin level observed in the blood serum of cancer patients. Detailed mechanistic study confirmed the presence of static ground state complexation and electrostatic interaction between the probe and the analyte, leading to quenching in fluorescence intensity of the probe. Real-time applications with the probe were performed in the unspiked serum samples of two normal people and two cancer patients (carcinoma valva and chronic myeloid leukemia) with significantly high ferritin content. Further analysis of PFBT-A in spiked normal blood serum samples showed good recoveries in the range of 102–102.5% with relative standard deviations (RSDs) within 1.07–1.16%, confirming the reliability and practical applicability of PFBT-A for ferritin detection in human blood serum. In the case of cancer blood serums, the recoveries were high, in the range of 105–109%, showing a high level of ferritin in cancer patients.

quote

GB/T 7714-2015 [1] Priyanka Dutta, Niranjan Meher, Akhtar Hussain Malik, et al. ACS Applied Polymer Materials, 2019(1). DOI:10.1021/acsapm.8b00016.
MLA [1] Priyanka Dutta, et al., ACS Applied Polymer Materials, no. 1, 2019, https://doi.org/10.1021/acsapm.8b00016.
APA [1] Priyanka Dutta, Niranjan Meher, Akhtar Hussain Malik, Bhaben Choudhury, & Parameswar Krishnan Iyer. (2019). ACS Applied Polymer Materials(1). https://doi.org/10.1021/acsapm.8b00016
IEEE [1] Priyanka Dutta, Niranjan Meher, Akhtar Hussain Malik, Bhaben Choudhury, and Parameswar Krishnan Iyer, ACS Applied Polymer Materials, no. 1, 2019, doi: 10.1021/acsapm.8b00016. keywords: {conjugated polymer−bioconjugate;ferritin;cancer biomarker;biosensing;blood serum fluorescence}