daohang fenxiangbox searchbox qikanlogonew daohangnew searchboxnew navrightzone footerzone paper

Electrochemical Desalination of Seawater and Hypersaline Brines with Coupled Electricity Storage AITranslate

PARC, A Xerox Company
AITranslate
Publisher: ACS
Share Citation Information Add to Favorites

    Scan to share on WeChat or Moments

Use WeChat scan.
Share with WeChat friends or Moments

Abstract AITranslate

We present a zinc|ferricyanide hybrid flow battery that achieves extensive first-pass desalination while simultaneously supplying electrical energy (10 Wh/L). We demonstrate 85% salt removal from simulated seawater (35 g/L NaCl) and 86% from hypersaline brine (100 g/L NaCl), together with reversible battery operation over 100 h with high round-trip efficiency (84.8%). The system has a high operating voltage (E0 = +1.25 V), low specific energy consumption (2.11 Wh/L for 85% salt removal), and a desalination flux (4.7 mol/m2·h) on par with that of reverse osmosis membranes. Salt removal was similarly effective at higher feed salinities, for which reverse osmosis becomes physically impossible because of the pressure required. The results have positive implications for regions that rely on desalination for their freshwater needs, especially where sea salinity is high. Alternatively, the battery may also be useful in minimal liquid discharge wastewater treatment if operated as a brine concentrator.

KeyWords AITranslate

No data

Basic Information:

DOI:https://doi.org/10.1021/acsenergylett.7b01220

Chinese Library Classification Number:

Citation Information:

We present a zinc|ferricyanide hybrid flow battery that achieves extensive first-pass desalination while simultaneously supplying electrical energy (10 Wh/L). We demonstrate 85% salt removal from simulated seawater (35 g/L NaCl) and 86% from hypersaline brine (100 g/L NaCl), together with reversible battery operation over 100 h with high round-trip efficiency (84.8%). The system has a high operating voltage (E0 = +1.25 V), low specific energy consumption (2.11 Wh/L for 85% salt removal), and a desalination flux (4.7 mol/m2·h) on par with that of reverse osmosis membranes. Salt removal was similarly effective at higher feed salinities, for which reverse osmosis becomes physically impossible because of the pressure required. The results have positive implications for regions that rely on desalination for their freshwater needs, especially where sea salinity is high. Alternatively, the battery may also be useful in minimal liquid discharge wastewater treatment if operated as a brine concentrator.

quote

GB/T 7714-2015 [1] Jessy B. Rivest. ACS Energy Letters, 2018(3). DOI:10.1021/acsenergylett.7b01220.
MLA [1] Jessy B. Rivest. ACS Energy Letters, no. 3, 2018, https://doi.org/10.1021/acsenergylett.7b01220.
APA [1] Jessy B. Rivest. (2018). ACS Energy Letters(3). https://doi.org/10.1021/acsenergylett.7b01220
IEEE [1] Jessy B. Rivest, ACS Energy Letters, no. 3, 2018, doi: 10.1021/acsenergylett.7b01220.